Product News

SANYO DENKI Develops UPS with Lithium-ion Battery
Industry’s widest operating temperature range

May 29, 2017

SANYO DENKI CO., LTD. has developed two types of UPS equipped with lithium-ion batteries: an outdoor UPS SANUPS N11B-Li and an online UPS SANUPS A11K-Li for indoor use.
These UPSs have the widest operating temperature range in the industry, ensuring stable operation even in extreme temperatures.
These are suitable for use in data centers, base stations, and outdoor surveillance cameras.

SANUPS A11K N11B

Features

1. The Widest Operating Temperature Range in the Industry*

A11K-Li and N11B-Li have wide operating temperature ranges of -20 to +55℃ and -20 to +50℃, respectively, both of which are leading in the industry. This ensures a carefree operation even in harshly cold or hot environments.

2. Space-Saving

The volume of the battery unit is approximately 1/2 that of our conventional UPS**, allowing these UPSs to be installed in smaller spaces.

3. Reduced Battery Maintenance

Lead-acid batteries used in our conventional UPS** need to be replaced every five years. These UPSs, however, are free from battery replacement for 10 years with lithium-ion batteries.

Note: This product is designed for use in Japan.

* Based on our own research as of May 29, 2017, among UPSs in the market with equivalent voltage and capacity.

** Our conventional UPS: A11K (with lead-acid battery)

Specifications

Model A11K-Li
Rated output capacity 1.5, 3, 5 kVA
UPS topology Double conversion online
Transfer time No interruption
Efficiency (AC-AC) 91%
AC input/output Rated frequency 50/60 Hz (Auto-negotiation)
Number of phases, wires Single-phase 2-wire
Rated voltage 100/110/120 V
Output power factor 0.8 (lagging)
Battery runtime* 30 to 400 min (Depends on the model)
Operating environment Ambient temperature: -20 to +55℃
Relative humidity: 10 to 90% (non-condensing)

* At 25℃ ambient temperature and load power factor of 0.8, under new, fully charged battery conditions.

Model N11B-Li
Rated output capacity 1, 1.5 kVA
UPS topology Passive standby
Transfer time 10 ms or less
Efficiency (AC-AC) 95%
AC input/output Rated frequency 50/60 Hz (Auto-negotiation)
Number of phases, wires Single-phase 2-wire
Rated voltage 100/110/120 V
Output power factor 0.8 (lagging)
Battery runtime* 150 min
Operating environment Ambient temperature: -20 to +50℃
Relative humidity: 20 to 90% (non-condensing)
Protection rating IP65

* At 25℃ ambient temperature and load power factor of 0.8, under new, fully charged battery conditions.

Applications

Data centers, base stations, and outdoor surveillance cameras

Release Date

June 5, 2017

Note: The information stated in this release is current as of May 29, 2017 .
“SANUPS” is a trademark of SANYO DENKI CO., LTD.